Author's Guide: Writing Workflows
Deprecated. Workflows are removed in 0.11, when tasks take over ordered steps. See STABILITY.md.
This guide walks through writing and testing a workflow definition: the Markdown structure, a minimal complete example, common authoring mistakes, and how to verify gates and outputs before you publish. It assumes you already know what a workflow is; for the exhaustive, exact-syntax reference — every frontmatter key, the reference grammar, gates, and outputs — see Workflow Schema. For operating a run once it's written, see Running Workflows.
Start from the template
A workflow is a Markdown file: OKF-conformant frontmatter carries the orchestration graph and the body carries instructions and gate rubrics.
Use akm workflow create --print to print a valid starter, then edit it and
register it with akm workflow create. Validate with akm lint:
akm workflow create my-release --print # Print the template, without writing
akm workflow create my-release --from ./my-release.md
akm lint --type workflows # Check for structural errors before using it
Markdown is the only workflow format. The GitHub-shaped .yml format was
removed in 0.10: a .yml file under workflows/ is skipped at index time with
a warning that it must use .md.
A minimal complete example
---
type: workflow
description: Ship a tagged release to production
params:
version: { type: string, description: The semver version string to release }
steps:
- id: validate
- id: build
inputs: [steps.validate.output]
---
# Ship Release
## validate
Check that the `version` parameter follows semver and the tag does not
already exist.
### gate
- `git tag v<version>` does not already exist.
- The version string matches `^\d+\.\d+\.\d+$`.
## build
Run `npm run build && npm test`, using the validation from `validate`,
attached to this unit as input. Fix any failures before proceeding.
Walking through it: validate and build are both bare unit steps — neither
declares unit: or map:, so each is "still a unit step," the
minimal declaration. build names steps.validate.output in inputs:, so
the engine attaches validate's result to build's dispatched context, and
build's own re-dispatch on a resumed run is keyed to that exact slice — not
the whole run. validate has a ### gate; build does not, so build
completes as soon as its unit succeeds, with no verification pass.
For a richer example — fan-out with map, retries,
and a run budget — see
Workflow Schema: Richer example.
Deterministic steps: run a command, gate on it
Not every step needs a model. Running the test suite, building, linting, or
invoking a script is deterministic work: there is exactly one right answer and
the command already knows it. A step whose unit: declares exec: runs that
command directly — no LLM, no agent, no tokens, no nondeterminism.
The canonical shape is a test step that gates the rest of the run:
---
type: workflow
description: Fix a failing test, then verify the suite is green
params:
failure: { type: string, description: The failing test name or error }
steps:
- id: fix
- id: test
inputs: [steps.fix.output]
unit:
exec:
command: ["bun", "run", "test:unit"]
timeout: "10m"
retry: { max: 1, on: [timeout] }
- id: report
inputs: [steps.test.output]
---
# Fix and Verify
## fix
Find the cause of the failure described in the run parameters and fix it.
Explain what you changed and why.
## test
Run the unit test suite. This step is deterministic: the command's exit code
decides whether the run continues.
## report
Summarize the fix and the test results attached to this unit.
What this buys you:
- The suite is the gate.
testuses the defaulton_error: fail, so a non-zero exit fails the unit withnon_zero_exit, fails the step, and stops the run beforereportever dispatches. No judge, no rubric, no prompt — the exit code is the verdict. - The output is real.
steps.test.outputis the command's stdout (trailing newlines stripped), soreportreceives the actual test output rather than a model's recollection of it. - It costs nothing. No tokens, no latency beyond the command itself, and the same input always produces the same dispatch.
- It resumes correctly. A completed exec unit is journaled like any other; a resumed run reuses the row instead of re-running the suite.
Getting a typed result instead of raw text
If the command can print JSON, declare an output schema on the unit and the
step artifact becomes a validated structure:
- id: test
unit:
exec:
command: ["bun", "run", "test:unit", "--reporter=json"]
output:
type: object
required: [passed, failed]
properties:
passed: { type: number }
failed: { type: number }
stdout must then be exactly one JSON value — no log noise around it — and
downstream steps can address steps.test.output.failed.
Agent in, exec out
A common pair is an agent step that writes something and an exec step that
acts on it. Give each unit its own output schema:
steps:
- id: draft
unit:
output:
type: object
required: [status, markdown]
additionalProperties: false
properties:
status: { type: string, enum: [done, blocked] }
markdown: { type: string, minLength: 1 }
- id: publish
inputs: [steps.draft.output]
unit:
exec:
command: ["node", "publish.mjs"]
output:
type: object
required: [posted]
properties:
posted: { type: boolean }
The command is an argv array, so nothing is spliced into it. publish.mjs
reads the draft from AKM_INPUTS, a JSON object keyed by each inputs:
reference string exactly as written, and prints one JSON value that matches
its own unit.output:
const inputs = JSON.parse(process.env.AKM_INPUTS ?? "{}");
const draft = inputs["steps.draft.output"];
// ...post draft.markdown; log to stderr, never stdout...
process.stdout.write(JSON.stringify({ posted: draft.status === "done" }));
The rule: a unit schema (unit.output) types that unit's result. A
step schema (step-level output:) validates the promoted step artifact,
which for a map step is the reducer's result. On a solo step with no
unit.output, a step-level output: is also used as the unit's schema;
writing it under unit: says so explicitly.
An agent that cannot do the work still "succeeds": it returns something that
fits the schema, such as status: blocked, and the step completes. If the run
must stop when the work was not done, make the unit schema require evidence
of the work, such as a required non-null string with minLength: 1 (a URL, a
path, a commit id) that the agent can only fill by doing it.
What the command can see
The command inherits your environment, as it would typed in your shell: PATH,
HOME, the toolchain variables and any credential of the process that ran akm run reach it. Then come your env: bindings, then the AKM_* context
variables. Ordinary commands (bun, git, make, cargo) work unchanged.
- id: build
unit:
env: [env/build]
exec:
command: ["cargo", "build", "--release"]
Fixed values belong in exact named env: bindings, and they reach the journal as
they are. A credential belongs in secrets/, bound by a ${secrets/name} token
inside the env asset; only values substituted from such a ref are redacted out of
everything journaled (see Binding a secret to a
unit). A value the
command inherited is not redacted.
exec.pass_env:, the list of names an earlier release copied into an otherwise
empty environment, still parses and selects nothing. Workflow starts freeze the
durable plan v4 family's current executable format (irVersion: 8), which
rejects inherit_env; the command inherits the environment without it.
Pre-irVersion-5 stored plans do not execute; start a new run after updating the
source.
Named bindings are part of the unit's input hash, so changing them re-runs the command instead of reusing a row recorded under another scope. What the command sees is described under Workflow Schema: The child's environment.
Using scripts, env and secrets from other bundles
A workflow in one bundle can run a script from a second bundle, with an env
asset from a third that names a secret in a fourth. Each is addressed by its akm
ref, [bundle//]conceptId, inside a ${...} token:
- id: status
unit:
env: [ci//env/status] # env/status.env in bundle ci
exec:
command: ["bun", "${tools//scripts/lab-status/fetch.ts}"]
# env/status.env in bundle ci
REGION=east
TOKEN=${vault//secrets/status_token}
${tools//scripts/...} becomes the script's absolute path when the unit
dispatches, ${vault//secrets/status_token} becomes the secret's value, and
REGION reaches the child as it is. Nothing in the plan records where any of
them lives, so updating a bundle in the middle of a run is harmless. The unit
runs in the root of the bundle that holds the workflow (cwd: is relative to
it, or absolute). See Workflow Schema: The exec
contract.
Things to get right
command:is an argv array, not a shell string.["bun", "run", "test"], never"bun run test". Nothing is shell-parsed; if you truly need a pipeline, write["bash", "-lc", "a | b"]and own that choice explicitly.- No interpolation of run data. The argv is frozen as authored; the only
substitution is a
${ref}token naming an asset. Amapstep's item reaches the command asAKM_ITEM(canonical JSON) and the run params asAKM_PARAMS— read them from the environment, do not try to splice them intocommand:. - Secrets go in
secrets/, bound throughenv:, never as literals incommand:.command:is stored as authored in the frozen plan;env:bindings are carried by name, and values substituted from a${secrets/name}ref are redacted out of everything journaled. - Long commands need a
timeout:. An exec unit defaults to 10 minutes. Usetimeout: "30m"for a slow suite, ortimeout: "none"only when you really mean unbounded. - The command has your shell's environment, so a credential in it reaches
it. Use a named
env:binding for a fixed or secret value you want redacted from the journal; a value the command inherited is not redacted. - A very chatty command still passes; its artifact just says so. akm retains
8 MiB of stdout and 8 MiB of stderr. Past that it keeps draining and discards,
so the command runs to completion and its exit code decides the step. The
artifact is then the retained head with a
__akm_exec_output_truncated__block appended, so nothing downstream can mistake it for the whole output. The one case that still fails is a unit with a declaredoutput:schema — a truncated prefix is not one JSON value, so there is nothing to validate. - Bulk data reaches a command as a path, not as an environment variable.
AKM_INPUTS/AKM_PARAMS/AKM_ITEMare bounded by what process creation accepts on the current platform (96 KiB per variable on Linux/macOS, 32 767 bytes on Windows). Over that, the unit failsexec_context_too_largebefore anything is spawned. If a workflow must also run on Windows, keep context under the Windows number — akm will not enforce it on your Linux box, but a Windows runner will.
Full reference: Workflow Schema: Exec (shell) units.
Common authoring mistakes
- Templating prose. There is no
${{ … }}/{{ … }}interpolation anywhere in a workflow body. Write instructions in plain language that refer to attached context — "using the intake step's artifact attached to this unit" — never by splicing a value into the string. See Workflow Schema: The reference grammar. - Mismatched or missing step headings. Every
## <step-id>must match a step declared in frontmatter exactly — no titles, noStep:/Step ID:lines, no# Workflow:prefix on the H1. - A
unit/mapstep with no body section. Its instructions (or, for a map step, its per-item template) are required. - Misplaced or misspelled
### gate. It is the format's single reserved marker, and it must be a###sub-heading inside the step's own section. An empty### gatesection is the same as omitting it — no verification runs. - Referencing an item outside a map unit.
item/item_indexare not part of the reference language anywhere — they only arrive as attached context inside that map step's own unit template. - Referencing an unknown step or param.
akm lint --type workflowschecks every bare reference statically (unknown step, unknown param, bad path) — run it before you rely on a workflow working. - Writing
exec.commandas a shell string.command: "bun run test"is rejected; it must be an argv array (["bun", "run", "test"]). Nothing is ever shell-parsed, so metacharacters inside an argument stay literal. - Listing names in
exec.pass_env:. It parses and selects nothing: the command already inherits your environment.pass_envlives insideexec:; the unit-levelenv:key is a list of exact env asset binding refs. A new v4 start rejectsinherit_env. - Asking a model to do deterministic work. "Run the test suite and tell me if it passed" is an exec step, not a prompt.
Typing what a step returns
An output: schema (and each params: entry) is a JSON Schema, and the engine
validates the result against it before the step can complete. The
runtime enforces a bounded subset of JSON Schema — anything outside it is
an authoring error at akm lint, never a silent no-op, because a gate
depending on a schema that constrains nothing is worse than a loud failure.
Enforced: type, enum, properties, required, items,
additionalProperties: false, minItems, maxItems, minLength,
maxLength, minimum, maximum, and the combinators allOf, anyOf,
oneOf, not.
- id: release
unit:
output:
type: object
required: [version, verdict]
additionalProperties: false
properties:
version: { type: string, minLength: 1 }
verdict: { type: string, enum: [pass, fail] }
detail:
oneOf:
- { type: string, minLength: 1 }
- { type: "null" }
release is a solo step, so its schema sits under unit: (see
Agent in, exec out).
Outside the subset (each fails lint with the keyword named, its line, and a
suggested replacement where one exists): $ref/$defs — inline the schema
instead, since nothing resolves references; const — use a single-value
enum; pattern and format — no regex or string-format constraint is
evaluated at run time, so list the allowed values with enum when you can,
bound the size with minLength/maxLength, and otherwise check the shape in
the step's ### gate rubric, which can also say why a value is wrong;
patternProperties, if/then/else, uniqueItems, multipleOf,
tuple-form items, and schema-form additionalProperties (only
additionalProperties: false is enforced). Annotation keywords —
description, title, default, examples — always pass through untouched,
and documenting each property is worth the keystrokes.
If lint reports a very broken workflow, note that its errors are sorted by line, so fix from the top and re-run — the later ones are usually fallout from the first.
Choosing where a step runs and which model
A step that dispatches a model runs on your default harness, or on akm's own
runtime over your default connection when you have no harness. Leave that to
the machine the workflow runs on. Name one only when a step needs it:
harness: or connection: in defaults (or per-unit unit.harness /
unit.connection), where a name the machine has not configured is an error that
names it and lists what the machine has, so a workflow shared across machines
should name a program only when it needs that one. Set defaults.model/unit.model to an alias rather
than hardcoding an exact model id, so the workflow stays portable. The aliases
are fast, balanced, reasoning and any a connection or harness maps in its
models; see
Workflow Schema: Model references
for the exact resolution order.
Point reasoning work at a capable model and keep high-volume fan-out units
on fast/balanced. The richer example's review map step is a good template: reasoning on the
per-item reviewer, balanced as the run default for everything else.
Fan-out width
A map step runs its items in parallel by default, 4 at a time. Map
units are independent by construction, so parallel is the default; the number
is a modest 4 rather than "whatever the machine can take" so it stays
predictable across the machines a workflow gets shared with.
Say so explicitly when the default is wrong for a step:
- id: review
map:
over: steps.discover.output.files
concurrency: 1 # serial — this step's units are NOT independent
concurrency: 1 is a genuine opt-out and always wins. Reach for it when the
units touch a shared resource, when their side effects must happen in list
order, or when they hit an external service you must not burst. To change the
default for every workflow on a machine instead, including making fan-out
serial wholesale, set
akm config set workflow.defaultMapConcurrency 1.
The declared width is a ceiling, not a promise. Three other limits clamp it
and the smallest wins: workflow.maxConcurrency, the selected connection's
concurrency, and the host's CPU cap. The connection limit is the one that
surprises people: a connection pointed at localhost defaults to 1, because
local model servers hold a single loaded model and fall over under concurrent
requests — so a map against a local model stays serial no matter what the step
declares, until you raise that connection's own concurrency. Remote endpoints
default to 4, and a step on a harness has no limit of this kind. See
Workflow Schema: Fan-out and concurrency
for the full table.
All of it is frozen into the run when it starts, so an in-flight or resumed run keeps the widths it began with even if you edit config or upgrade akm.
A fan-out runs N agents at once, not one. Document every params entry and
describe destructive steps plainly in the body, so a reader (human or agent)
can see what a run will do before starting it.
Verify before you publish
-
Lint the structure.
akm lint --type workflowsThis catches the body-rule violations above, plus every static reference check (unknown step, unknown param, bad path).
-
Run it for real. A dry inspection of the markdown doesn't tell you whether a gate actually rejects bad output or an
outputschema actually matches what units return. Run the workflow against representative params:akm run workflows/my-release --version 1.2.3 -
Inspect the evidence. Check that each step's promoted artifact is what you expect, and that a gate's rubric is judging that artifact, not engine prose:
akm workflow status <run-id> --units--unitsshows per-unit diagnostics (status,failure_reason, raw result/error text) without polluting the deterministic artifact a gate judges — see Running Workflows: Check status. -
Deliberately break a gate once. Run the workflow with params you expect to fail validation, and confirm the gate actually rejects rather than silently passing — a missing judge (no connection or harness to run it) or a malformed verdict rejects the gate rather than bypassing it (see Workflow Schema: Gates and verification), so this is worth confirming once per workflow rather than assuming.
Running a child workflow (Experimental)
A step can run another workflow and use its result. The step names the child
in its unit: bag and binds the child's params: with with::
---
type: workflow
params:
topic: { type: string }
steps:
- id: investigate
unit:
workflow: workflows/research
with:
topic: { from: params.topic }
- id: report
inputs: [steps.investigate.output]
---
## investigate
Runs the research workflow as a child run.
## report
Summarise the research finding.
A with: value is a literal (checked against the child's param type when the
workflow is frozen) or { from: <reference> }, where the reference is
params.<name> or steps.<id>.output(.<segment>)*, resolved just before the
step runs. The child's last step output is the composing step's output, so
report reads it through inputs:. Inspect what a step would pass, without
running anything, with akm doctor explain workflows/<name> --format json; the
per-step inputBindings show each literal and each unresolved reference.
Child workflows are Experimental. See Workflow Schema: Child workflows for blocked-child recovery and the limits.
Troubleshooting
A step that dispatches a model needs a harness or a connection. Freezing
resolves where each unit runs: its unit.harness or unit.connection, else the
document's defaults, else your default harness, else akm's own runtime over
your default connection. With none of those, freezing fails and the error points
at akm setup. A workflow made only of exec steps needs neither.
A workflow with a non-empty ### gate also needs one for the gate judge, which
runs where model work runs: your default connection, else your default harness.
An exec-only workflow with a gate still needs it.
akm setup normally configures both. On a bare container or CI image, run it
with the answers as flags, or add one by hand:
akm setup --yes --endpoint http://localhost:11434/v1 # a model endpoint
akm setup --yes --harness claude # or an agent program you have
See also
- Workflow Schema — exact frontmatter, refs, gates, and outputs syntax
- Running Workflows — start, inspect, resume, and abandon a run
- Architecture: The Workflow Engine — persistence, dispatch, and resume internals
- CLI Reference — full flag documentation for
workflow create,run, andlint